- UV Lamp[1]
- Chargers[1]
- Solar Cells[1]
- Circuit Breakers[30]
- Terminal Blocks[1]
- Terminals[4]
- Contactors[30]
- Electrical Plugs & Sockets[11]
- Electronic & Instrument Enclosures[1]
- Fuse Components[4]
- Fuses[7]
- Other Electrical Equipment[10]
- Power Accessories[2]
- Power Distribution Equipment[2]
- Inverters & Converters[3]
- Switching Power Supply[5]
- Uninterrupted Power Supply (UPS)[5]
- Voltage Regulators/Stabilizers[12]
- Relays[27]
- Micro Switches[2]
- Other Switches[15]
- Push Button Switches[1]
- Rotary Switches[4]
- Toggle Switches[1]
- Wall Switches[2]
- Other Wires[2]
- Cable Glands[5]
- Wiring Ducts[4]
- Diodes[1]
- Rectifiers[1]
- Thyristors[2]
- Insulation Materials & Elements[2]
- Other Electronic Accessories[2]
- Resistors[1]
- Solar Chargers[1]
- Food Waste Disposers[1]
- Starters[2]
- Energy Saving & Fluorescent[3]
- LED Bulbs & Tubes[1]
- Emergency Lights[8]
- LED Lamps[30]
- Other LED Lighting[1]
- Camping Lights[1]
- Street Lights[1]
- Floor Lamps[1]
- Other Lights & Lighting Products[1]
- Arc Welders[13]
- Other Welding Equipment[3]
- Counters[2]
- Clamp Meters[1]
- Current Meters[1]
- Energy Meters[10]
- Frequency Meters[1]
- Multimeters[1]
- Power Meters[1]
- Voltage Meters[2]
- Other Measuring & Analysing Instruments[1]
- Temperature Instruments[1]
- Testing Equipment[7]
- Timers[3]
- Alarm[7]
- Locks[1]
- Other Police & Military Supplies[1]
- Traffic Light[2]
Indoor HV Load Switch - fuse
Product Detailed
Isolate Switch
1.Type:FN12
2.Standard|:IEC GB
3.Main Material:Procelain&Steel
Outline
FN12-12D and FN12-12DRSwitchgear is a rated voltage of 12kV, rated frequency 50Hz three-phase high-voltage switchgear for the division and load current, Loop current, no load transformer and cable charging current, short circuit current of the Closing, fuse may short-circuit breaking current, with equipment grounding switch load switch that can withstand short-circuit current, mainly for three-phase power s../upply ring network city distribution and industrial power equipment for load control and short circuit protection.
Main technical parameters
Serial number | Project | Unit | FN12-12/630 | FNR12-12/100-31.5 |
1 | Rated voltage | kV | 12 | |
2 | Rated frequency | Hz | 50 | |
3 | Rated Current | A | 630 | 125 |
4 | Lightning impulse withstand voltage | kV | On the ground and 75 isolation fracture85 | |
5 | 1minFrequency withstand voltage | kV | 42 on the ground and white, isolated fracture48 | |
6 | Rated thermal current | kA | 20(4S) | |
7 | Rated dynamic current | kA | 50 | |
8 | Rated short circuit making current (peak) | kA | 50 | 50 |
9 | Rated short-circuit breaking current (projected) | kA | 31.5 | |
10 | Rated transfer current | kA | 1.5 | |
11 | Operating Agency | KVA | 1250 | |
12 | Rated cable charging current | A | 10 | |
13 | Mechanical life | Times | 4000 | |
14 | Fuse switches gate trigger load time | S | <0.06 | |
15 | Ground thermal current switch | kA | 20(4S) | |
16 | Grounding switch dynamic current (peak) | ka | 50 | |
17 | Control circuit supply voltage |