- UV Lamp[1]
- Chargers[1]
- Solar Cells[1]
- Circuit Breakers[30]
- Terminal Blocks[1]
- Terminals[4]
- Contactors[30]
- Electrical Plugs & Sockets[11]
- Electronic & Instrument Enclosures[1]
- Fuse Components[4]
- Fuses[7]
- Other Electrical Equipment[10]
- Power Accessories[2]
- Power Distribution Equipment[2]
- Inverters & Converters[3]
- Switching Power Supply[5]
- Uninterrupted Power Supply (UPS)[5]
- Voltage Regulators/Stabilizers[12]
- Relays[27]
- Micro Switches[2]
- Other Switches[15]
- Push Button Switches[1]
- Rotary Switches[4]
- Toggle Switches[1]
- Wall Switches[2]
- Other Wires[2]
- Cable Glands[5]
- Wiring Ducts[4]
- Diodes[1]
- Rectifiers[1]
- Thyristors[2]
- Insulation Materials & Elements[2]
- Other Electronic Accessories[2]
- Resistors[1]
- Solar Chargers[1]
- Food Waste Disposers[1]
- Starters[2]
- Energy Saving & Fluorescent[3]
- LED Bulbs & Tubes[1]
- Emergency Lights[8]
- LED Lamps[30]
- Other LED Lighting[1]
- Camping Lights[1]
- Street Lights[1]
- Floor Lamps[1]
- Other Lights & Lighting Products[1]
- Arc Welders[13]
- Other Welding Equipment[3]
- Counters[2]
- Clamp Meters[1]
- Current Meters[1]
- Energy Meters[10]
- Frequency Meters[1]
- Multimeters[1]
- Power Meters[1]
- Voltage Meters[2]
- Other Measuring & Analysing Instruments[1]
- Temperature Instruments[1]
- Testing Equipment[7]
- Timers[3]
- Alarm[7]
- Locks[1]
- Other Police & Military Supplies[1]
- Traffic Light[2]
Indoor HV load switch and fuse
Product Detailed
Isolate Switch
1.Type:FN5-12
2.Standard|:IEC420 GB3804
3.Main Material:Procelain&Steel
Outline
FN7——12DRModel Indoor AC HV Load Switch is suitable in 50Hz, rated voltage of 12Kv the three-phase AC power system as the breaking load short-circuit current of the power and used the Closing, until the combination of electrical short-circuit current can be breaking any current can be used as protection purposes.
Installation and use of
Ambient air temperature Limit +40°C Lower limit -25°C
Above sea level1000m.
Relative humidity: daily average is less than 95%, on average less than 90%;
The surrounding air should not be corrosive or flammable gases and water vapor and other obvious contamination;
Without frequent violent vibration.
Rated parameters
Rated voltage (KV rms) | 12 | ||
Insulation level | 1min power frequency withstand voltage (KV. RMS) | White. Phase to 42 | Isolation break48 |
Lightning impulse voltage (KV. a peak) | White. Phase to 75 | Isolation break85 | |
Rated Current(A) | 400 | 630 | |
Rated thermal current (KA RMS 4S) | 12.5 | 20 | |
Rated dynamic current KA (peak) | 31.5 | 50 | |
Rated short circuit making current (KA peak) | 31.5 | 50 |
Specifications
Name | Name | All models | DS | DX | L | R | RA | F | Use |
Grounding switch into the line-side | Grounding switch outlet side | Interlock device | Fuse | Impact fuse | Electric sub-gate devices | ||||
Load Switches | Non-impact fuse | FN7—12 | —— | —— | —— | —— | —— | —— | Line load switch |
FN7—12DSL | Y | —— | Y | —— | —— | —— | |||
FN7—12DXL | —— | Y | Y | ||||||
FN7—12R | —— | —— | —— | Y | —— | —— | Transformer Protection | ||
FN7—12DSLR | Y | —— | Y | Y | —— | —— | |||
FN7—12DXLR | —— | Y | Y | Y | —— | —— | |||
With impact fuse | FN7—12RAF | —— | —— | —— | —— | Y | Y | Transformer Protection | |
FN7—12DSLRAF | Y | —— | Y | —— | Y | Y | |||
FN7—12DXLRAF | —— | Y | Y | —— | Y | Y |
Other products