- UV Lamp[1]
- Chargers[1]
- Solar Cells[1]
- Circuit Breakers[30]
- Terminal Blocks[1]
- Terminals[4]
- Contactors[30]
- Electrical Plugs & Sockets[11]
- Electronic & Instrument Enclosures[1]
- Fuse Components[4]
- Fuses[7]
- Other Electrical Equipment[10]
- Power Accessories[2]
- Power Distribution Equipment[2]
- Inverters & Converters[3]
- Switching Power Supply[5]
- Uninterrupted Power Supply (UPS)[5]
- Voltage Regulators/Stabilizers[12]
- Relays[27]
- Micro Switches[2]
- Other Switches[15]
- Push Button Switches[1]
- Rotary Switches[4]
- Toggle Switches[1]
- Wall Switches[2]
- Other Wires[2]
- Cable Glands[5]
- Wiring Ducts[4]
- Diodes[1]
- Rectifiers[1]
- Thyristors[2]
- Insulation Materials & Elements[2]
- Other Electronic Accessories[2]
- Resistors[1]
- Solar Chargers[1]
- Food Waste Disposers[1]
- Starters[2]
- Energy Saving & Fluorescent[3]
- LED Bulbs & Tubes[1]
- Emergency Lights[8]
- LED Lamps[30]
- Other LED Lighting[1]
- Camping Lights[1]
- Street Lights[1]
- Floor Lamps[1]
- Other Lights & Lighting Products[1]
- Arc Welders[13]
- Other Welding Equipment[3]
- Counters[2]
- Clamp Meters[1]
- Current Meters[1]
- Energy Meters[10]
- Frequency Meters[1]
- Multimeters[1]
- Power Meters[1]
- Voltage Meters[2]
- Other Measuring & Analysing Instruments[1]
- Temperature Instruments[1]
- Testing Equipment[7]
- Timers[3]
- Alarm[7]
- Locks[1]
- Other Police & Military Supplies[1]
- Traffic Light[2]
ADL900 Type Frequency Inverter
Product Detailed
1.Input Rated voltage:Single phase 220V,three-phase 220V; 2.Output Rated voltage:0-220V
3.Output Frequency range:0Hz-400Hz
1.Specification
Input | Rated voltage / frequency Allowable | Single phase 220V,three-phase 220V; 50Hz/60Hz Variation value voltage: -20% to+20%; Voltage imbalance rate: 3%; frequency:5 |
Output | Rated voltage | 0-220V |
Frequency range | 0Hz-400Hz | |
Frequency resolution | 0.01Hz | |
Overload capacity | Type G: 150% rated current for1 minute;180% for1second; 200%for instantaneous protection Type P:120% rated current for1minute;150% for 1 second;180% for instantaneous protection | |
Modulation mode | Optimized space voltage vector PWM modulation | |
Frequency accuracy | Digital setting: maximum frequency X ± 0.01%; Analog setting: maximum frequency X ± 0.2% | |
Frequency resolution | Digital setting: 0.01Hz; analog setting:maximum frequency x0.1% | |
Start frequency | 0.40Hz-10.00Hz | |
Torque increase | Automatic torque increase Manually operated torque increase by 0.1%-30.0%(V/Fmode valid) | |
V/F curve Linear | V/Fcurve,square V/F curve, user defined V/F curve | |
Main control function | Acceleration and deceleration time | Unit of time (min/sec) optional, max. 3600 (0.1-3600) |
DC braking | The startand shutdown hour and minute are selectable. Action frequency: 0-20.00Hz Action duration: 0-30.0 seconds; braking current: 0-80% | |
Jog | Jog frequency range: 0.1Hz-50.00Hz Jog acceleration and deceleration time: 0.1-3600 seconds | |
Built-in PID | The closed loop control system can be conveniently process | |
Multi-speed operation Weaving wobble frequency | Multi-speed operation is realized through built-in PLC or control terminal Swing amplitude-fixed and variable swing amplitude | |
Automatic voltage regulation (AVR) | The output voltage is kept constant in case of grid voltage change | |
Automatic energy-saving operation | The V/F curve is automatically optimized according to load conditions so as to realize energy-saving operation |
Operation function | Automatic current limiting | Perform automatic current limiting during operation to prevent tripping due to frequent over-current fault |
Communication function | With RS485 standard communication interface; support MODBUS communication protocols in ASCII and RTU format. Master-slave machines reaction is available | |
Run command channel | Operation panel defined; control terminal de fined; serial port defined;switching among the three modes | |
Frequency settingchannel | Keyboard analog potentiometer defined; keyboard keys ↑ and ↓ defined; function code digit defined; serial port defined;terminal UP/ DOWN defined; analog voltage defined;analog defined;pulse defined;combination defined; switching among several given modes | |
Switchinput channel | Positive reversal command; 5-way programmable on-off input; 35 functions can be set separately. | |
Analoginput channel | 2-way analog signal input; 4-20mA,0-10 Voptional | |
Analog output channel | Analog signal output, 4-20 mA or 0-10V optional; physical output of set frequency and output frequency is available | |
Operation panel | LED digital display | Indicating the parameters like set frequency,output voltage and current output |
External instrument | Indicating the physical parameters like set frequency, output voltage and current output | |
Protection function | Over-current protection; over-voltage protection; under-voltage protection; over-heating protection; overload protection etc. | |
Options | Brake assemblies; remote operation panel; remote cable; keyboard mounting base etc. | |
Environment Location | Indoor;away from direct sunlight;freeofdust, corrosive gases,oil mist and water vapor etc. | |
Height above sea level | <1000m( de-rated when used at a height of more than 1000m) | |
Ambient temperature | -10 oC~+40 oC | |
Humidity | <90%RH,no condensation | |
Vibration | <5.9m/s2(0.6G) | |
Structure | Storage temperature | -20 oC~+60 oC |
Degree of protection | IP20 (when either status display unit or keyboard is used) | |
Cooling method | Air-blast cooling | |
Installation method | Wall mounted |