Andeli Group Co., Ltd.

ADL900 Type Frequency Inverter

ADL900 Type Frequency Inverter
Product Detailed

1.Input Rated voltage:Single phase 220V,three-phase 220V; 2.Output Rated voltage:0-220V
3.Output Frequency range:0Hz-400Hz

1.Specification
Item Standard Specification
InputRated voltage / frequency AllowableSingle phase 220V,three-phase 220V; 50Hz/60Hz Variation value voltage: -20% to+20%; Voltage imbalance rate: 3%; frequency:5
OutputRated voltage0-220V
Frequency range0Hz-400Hz
Frequency resolution0.01Hz
Overload capacityType G: 150% rated current for1 minute;180% for1second; 200%for instantaneous protection Type P:120% rated current for1minute;150% for 1 second;180% for instantaneous protection
Modulation modeOptimized space voltage vector PWM modulation
Frequency accuracyDigital setting: maximum frequency X ± 0.01%; Analog setting: maximum frequency X ± 0.2%
Frequency resolutionDigital setting: 0.01Hz; analog setting:maximum frequency x0.1%
Start frequency0.40Hz-10.00Hz
Torque increaseAutomatic torque increase Manually operated torque increase by 0.1%-30.0%(V/Fmode valid)
V/F curve LinearV/Fcurve,square V/F curve, user defined V/F curve
Main control functionAcceleration and deceleration timeUnit of time (min/sec) optional, max. 3600 (0.1-3600)
DC brakingThe startand shutdown hour and minute are selectable. Action frequency: 0-20.00Hz Action duration: 0-30.0 seconds; braking current: 0-80%
JogJog frequency range: 0.1Hz-50.00Hz Jog acceleration and deceleration time: 0.1-3600 seconds
Built-in PIDThe closed loop control system can be conveniently process
Multi-speed operation Weaving wobble frequencyMulti-speed operation is realized through built-in PLC or control terminal Swing amplitude-fixed and variable swing amplitude
Automatic voltage regulation (AVR)The output voltage is kept constant in case of grid voltage change
Automatic energy-saving operationThe V/F curve is automatically optimized according to load conditions so as to realize energy-saving operation

Item Standard Specification
Operation functionAutomatic current limitingPerform automatic current limiting during operation to prevent tripping due to frequent over-current fault
Communication functionWith RS485 standard communication interface; support MODBUS communication protocols in ASCII and RTU format. Master-slave machines reaction is available
Run command channelOperation panel defined; control terminal de fined; serial port defined;switching among the three modes
Frequency settingchannelKeyboard analog potentiometer defined; keyboard keys ↑ and ↓ defined; function code digit defined; serial port defined;terminal UP/ DOWN defined; analog voltage defined;analog defined;pulse defined;combination defined; switching among several given modes
Switchinput channelPositive reversal command; 5-way programmable on-off input; 35 functions can be set separately.
Analoginput channel2-way analog signal input; 4-20mA,0-10 Voptional
Analog output channelAnalog signal output, 4-20 mA or 0-10V optional; physical output of set frequency and output frequency is available
Operation panelLED digital displayIndicating the parameters like set frequency,output voltage and current output
External instrumentIndicating the physical parameters like set frequency, output voltage and current output
Protection functionOver-current protection; over-voltage protection; under-voltage protection; over-heating protection; overload protection etc.
OptionsBrake assemblies; remote operation panel; remote cable; keyboard mounting base etc.
Environment LocationIndoor;away from direct sunlight;freeofdust, corrosive gases,oil mist and water vapor etc.
Height above sea level<1000m( de-rated when used at a height of more than 1000m)
Ambient temperature-10 oC~+40 oC
Humidity<90%RH,no condensation
Vibration<5.9m/s2(0.6G)
StructureStorage temperature-20 oC~+60 oC
Degree of protectionIP20 (when either status display unit or keyboard is used)
Cooling methodAir-blast cooling
Installation methodWall mounted